Digital Fax status is undefined/stopped and won't start - Windows fax service crash with faulting module FXSTIFF.dll

Applies from Application Suite 201x (any version)
to version Application Suite 2017.3.2

Applies to

Microsoft Windows Server 2008/2008 R2 and Microsoft Windows Server 2012/2012 R2 
 

Description

The Fax Service encountered a problem and needed to close.
Error Code: 0x00000000
This error code indicates the cause of the error.
A Windows Error Report was generated with full details about the problem.
The Fax service will restart now.

Faulting application name: fxssvc.exe, version: 6.1.7601.17514, time stamp: 0x4ce7b339
Faulting module name: FXSTIFF.dll, version: 6.1.7601.17514, time stamp: 0x4ce7c672
Exception code: 0xc0000005
Fault offset: 0x000000000005c462
Faulting process id: 0x16c0
Faulting application start time: 0x01d105096a32fab8รน
Faulting application path: C:\Windows\system32\fxssvc.exe
Faulting module path: C:\Windows\system32\FXSTIFF.dll
Report Id: b4792b9c-70fc-11e5-a270-782bcb1ef55a

Cause

The problem is due to a bug of Windows Fax Service and PaperSize Configuration

Solution

Then follow this procedure: