Regardless the recording mode you wish to implement, you need to configure a SIP Trunk for Imagicle Call Recording.
SIP Trunk configuration
-
Create a new SIP Trunk Security Profile named “Imagicle Call Recording SIP Security Profile” with following settings.
-
Incoming Transport Type: TCP + UDP
-
Outgoing Transport Type: UDP
-
Incoming Port: 5070
-
Enable Digest Authentication: disabled
-
Enable Application Authorization: disabled
-
Accept Unsolicited Notification: enabled
-
Accept Replaces Header: enabled
Leave all other settings to their default value.
-
Define a new SIP Profile named "Imagicle Call Recording SIP Profile", with following settings:
-
Timer Invite Expires: 5
-
Retry INVITE: 1
-
SIP OPTIONS PING - Enable OPTIONS Ping: Enabled
-
SIP OPTIONS PING - Ping interval for In- service Trunks: 10
-
SIP OPTIONS PING - Ping interval for Out-of-service Trunks: 5
-
SIP OPTIONS PING - Ping Retry Timer: 500
-
SIP OPTIONS PING - Ping Retry Count: 3
Leave all other settings to their default value.
-
Create a new SIP Trunk named “Imagicle Call Recording Primary SIP Trunk” with following settings:
-
Device name: Imagicle_CallRecording_Primary_SIP_Trunk
-
Call Classification: On-Net
-
Media Resource Group List: Assign a Media Resource Group List
-
Run on all Active Unified CM Nodes: Enabled
-
SIP Information - Destination Address: <Imagicle server IP/FQDN>
-
SIP Information - Destination port: 5070
-
SIP Trunk Security Profile: Imagicle Call Recording SIP Security Profile (see above)
-
SIP Profile: Imagicle Call Recording SIP Profile (see above)
-
DTMF Signalling Method: RFC2833
Leave all other settings to their default value.