Imagicle UCX Suite 2019.Spring.1.H1 known problems
Description
Imagicle UCX Suite 2019.Spring.1.H1 is affected by the following problems:
PAEXec missing during first install or upgrade from UCX Suite version < Winter.2017.1
Error during new cluster creation via HighAvailability menu in UCX Suite Admin Web Page
1. PAEXec is missing issue
Running the installer of 2019.Spring.1.H1 could display the following error message: "Program "paexec.exe" failed to execute: The system cannot find the file specified."

Cause
PAExec executable is missing in IAS installation folder (e.g. C:\Program Files (x86)\StonevoiceAS\Lib\Paexec).
Solution
Create a new folder Paexec in <StonevoiceAS>\Lib
Download paexec_file.zip
Exctract it in <StonevoiceAS>\Lib\Paexec
Click on Retry in order to continue the installation
2. Cluster creation failed issue
When an Administrator tries to create a new cluster via HighAvailability UCX Suite Web Page using Spring.2019.1.H1, the following error message could be displayed: "An error occurred during local node initialization".

Cause
erl_inetrc.config file is missing in RabbitMQ folder (e.g. C:\Program Files (x86)\StonevoiceAS\Lib\RabbitMQ).
Solution
Navigate to <StonevoiceAS>\Lib\RabbitMQ
Duplicate erl_inetrc.config.template file and rename it in erl_inetrc.config
Retry cluster creation operation via Admin Web Page